『woltmann water meter』Related information(flow rotameter|digital flow meter|balo meter|hydraulic flow meter|volumetric meter|positive displacement meter|pitot tube flow meter|displacement meter|cfm meter|variable area flow meter|inline flow meter|differential pressure flow meter|calibrated flow meter|velocity meter|paddle wheel flow meter|oval gear flow meter|anemometer hvac|multiphase flow meter|doppler flow meter|thorpe tube flowmeter|heat flow meter)

1. Water meter pressure loss?
National Standard of the Peoples Republic of China Cold Water Meter Part 1: Specification Measuerment of water flow in closed conduits GB/T 778.1-1996-Meters for cold potable water eqv ISO4064-1:1993 -Part 1:Specifications This standard replaces the scope of GB778-841 and is part 1 of GB/T778, covering terminology, technical characteristics, metrological characteristics, and pressure loss. This standard is applicable to water meters of different measurement levels (Chapter 5) with a commonly used flow range of 0.6-4000m3/h, a maximum allowable working pressure (MAP) equal to or greater than 1MPa, and a maximum allowable temperature (MAT) of 30 ° C. This standard is only applicable to volumetric and velocity water meters. GB/T 778 stipulates that eggplants must comply with regulatory requirements. The articles included in the following standards are referred to as articles of this standard by reference. At the time of publication, all versions shown are valid. All standards will be revised, and parties using this standard should explore the possibility of using the latest versions of the following standards. GB 4208-93 Degrees of Protection Provided by Enclosures (IP Code) GB 4216.4-84 10 bar Grey Cast Iron Pipe Flange Dimensions GB 7306-87 Pipe Threads Sealed with Threads GB 7307-87 Non Threaded Sealed Pipe Threads 3 Definitions This standard adopts the following definitions: 3.1 Volumetric meter is a water meter installed in a closed pipeline, consisting of chambers of known volume that are gradually filled and discharged with fluid and a mechanism driven by the fluid. By calculating the volume of water flowing through the device, the volume of water flowing out can be accu

3.4 Common flow rate (qp) The optimal flow rate for a permanent flow rate water meter under normal working conditions, i.e. stable or intermittent flow
3.5 Overload flow rate (qs) The maximum flow rate that an overload flow rate water meter can use in a short period of time without damage. Its value is twice the commonly used flow rate
3.6 Minimum flow rate (qmin) The minimum flow rate that requires the water meter to provide a value within the maximum allowable error limit. It is related to the numerical value of the water meter code. The flow rate range is defined by the minimum flow rate and overload flow rate, and within this range, the reading of the water meter shall not produce errors exceeding th

Current position > Product detail